diff --git a/ampel-firmware/ampel-firmware.ino b/ampel-firmware/ampel-firmware.ino index d45326baed5b769cba0bbdd5d820447d349bb192..7734e620a80eeed1ed9a32921c494e37603d1df8 100644 --- a/ampel-firmware/ampel-firmware.ino +++ b/ampel-firmware/ampel-firmware.ino @@ -171,7 +171,6 @@ void loop() { if (sensor::processData()) { if (config::csv_active()) { - //TODO: Check if not in AP mode. Lines get written with 1970 otherwise. csv_writer::logIfTimeHasCome(sensor::timestamp, sensor::co2, sensor::temperature, sensor::humidity); } diff --git a/ampel-firmware/src/lib/NTPClient/NTPClient.h b/ampel-firmware/src/lib/NTPClient/NTPClient.h index f4eb2994c3221a8bfe7460683598a774d5950a7c..5df9e7a70acf2947e4a5be2da5cc497850daaa09 100755 --- a/ampel-firmware/src/lib/NTPClient/NTPClient.h +++ b/ampel-firmware/src/lib/NTPClient/NTPClient.h @@ -20,7 +20,7 @@ class NTPClient { unsigned long _updateInterval = 60000; // In ms - unsigned long _currentEpoc = 0; // In s + unsigned long _currentEpoc = 1640995200; // NOTE: Custom code for ampel-firmware : Default is 1st January 2020. Better than 1970 unsigned long _lastUpdate = 0; // In ms byte _packetBuffer[NTP_PACKET_SIZE]; diff --git a/ampel-firmware/web_config.cpp b/ampel-firmware/web_config.cpp index d165a1351c279ca5764d7facb4e811cc6d06d7be..51aa30d75ffc0d333f6e400ab1f743e10aab5ee7 100644 --- a/ampel-firmware/web_config.cpp +++ b/ampel-firmware/web_config.cpp @@ -127,7 +127,6 @@ namespace web_config { * NTP Time */ - //NOTE: Save time after first NTP connection, so that time doesn't go back to 1970? ParameterGroup timeParams = ParameterGroup("NTP", "Time server"); TextTParameter<STRING_LEN> ntpServerParam = Builder<TextTParameter<STRING_LEN>>("ntp_server").label("NTP Server").defaultValue(NTP_SERVER).build();