Skip to content
GitLab
Projects Groups Snippets
  • /
  • Help
    • Help
    • Support
    • Community forum
    • Submit feedback
  • Sign in
  • ampel-firmware ampel-firmware
  • Project information
    • Project information
    • Activity
    • Labels
    • Members
  • Repository
    • Repository
    • Files
    • Commits
    • Branches
    • Tags
    • Contributors
    • Graph
    • Compare
    • Locked Files
  • Issues 2
    • Issues 2
    • List
    • Boards
    • Service Desk
    • Milestones
    • Iterations
    • Requirements
  • Merge requests 0
    • Merge requests 0
  • CI/CD
    • CI/CD
    • Pipelines
    • Jobs
    • Schedules
    • Test Cases
  • Deployments
    • Deployments
    • Environments
    • Releases
  • Packages and registries
    • Packages and registries
    • Package Registry
    • Infrastructure Registry
  • Monitor
    • Monitor
    • Incidents
  • Analytics
    • Analytics
    • Value stream
    • CI/CD
    • Code review
    • Insights
    • Issue
    • Repository
  • Wiki
    • Wiki
  • Snippets
    • Snippets
  • Activity
  • Graph
  • Create a new issue
  • Jobs
  • Commits
  • Issue Boards
Collapse sidebar
  • co2ampelco2ampel
  • ampel-firmwareampel-firmware
  • Issues
  • #1
Closed
Open
Issue created Apr 01, 2021 by Käppler@michael_kaepplerContributor

First CO2 measurement often unreliable

When powering the sensor on after being moved to a new room with substantially different CO2 concentration, the first measurement is often highly unreliable, e.g. showing 600 ppm and a minute later 1200 ppm. I would suspect this is due to the SCD30's response time, reaching 63% of the final value after 20s, in combination with the default measurement interval of 60s.

https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/9.5_CO2/Sensirion_CO2_Sensors_SCD30_Datasheet.pdf

This is unproblematic, if the sensor stays in the same place and runs continuosly, though.

Edited Apr 01, 2021 by Käppler
Assignee
Assign to
Time tracking