Commit f62e75e8 authored by Kai-Holger Brassel's avatar Kai-Holger Brassel
Browse files

Add reference and two typos

parent 9455890d
......@@ -709,6 +709,8 @@ Changes in data model also can make existing XML data incompatible. There are to
=== Add Units to the Mix
As mentioned earlier, parameter catalogs should be able to represent quantities, not just bare numbers.
See https://onlinelibrary.wiley.com/doi/full/10.1002/spe.2926[Unit of measurement libraries, their popularity and suitability] for a systematic account of open source solutions in the this area.
Java provides an extensive framework to deal with quantities and their units defined in https://docs.google.com/document/d/12KhosAFriGCczBs6gwtJJDfg_QlANT92_lhxUWO2gCY/edit#heading=h.6698n7erex5o[Java Specification Request (JSR) 385].
The reference implementation for this framework is https://unitsofmeasurement.github.io/indriya/[Indriya]. Demos of its usage can be found at https://unitsofmeasurement.github.io/uom-demos/[].
......@@ -740,7 +742,7 @@ Note here, that I also changed the default value from `0.0` to `0.0 V` to indica
The symbols for defining units follow SI and other standards, including decimal prefixes like `m` for Milli or `G` for Giga as well as derived units, that is: `mV`, `GV` or `kW·h/m³` are all valid unit definitions. This is all documented well in the resources mentioned at the top of this section, but for convenience, a table with valid units, including some specific units for urban simulation, is compiled in link:UnitsExamples.md[].
If a unit symbol cannot be interpreted, this error is not already detected while generating and compiling code from model, but not before runt time when the application tries to create the default value. In that case, you will see an error message like this:
If a unit symbol cannot be interpreted, this error is not already detected while generating and compiling code from model, but not before run time when the application tries to create the default value. In that case, you will see an error message like this:
.Error Message for Wrong Unit Definition
image::ErrorInUnitDefinition.png[Install Plug-in , 400, role="thumb"]
......@@ -758,7 +760,7 @@ One last technicality. *Before* code from an Ecore model with attributes of type
. Choose `Ecore model`, press `Next >` and `Load` the model (again)
. `Next >` will open the page below. In section _Referenced Generator Models_ select the Quantities generator model as depicted and click on `Finish`.
.Add Reference to imported Generator Model
.Add Reference to Imported Generator Model
image::ReferenceGeneratorModel.png[Install Plug-in , 500, role="thumb"]
If no generator model is available for selection, press button `Add...` to add it first (this only works if `QuantityLong` or `QuantityDouble` were used at least once in the Ecore model).
......
Supports Markdown
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment